Study and time History Analysis of G+12 RCC Hospital Building in Seismic Zone III using ETABS

Authors

  • MD Nasim Ansari, Prof. Pawan Dubey

Keywords:

Seismic retrofitting, RC jacketing, storey displacement, base shear, ETABS analysis

Abstract

This research evaluates the seismic performance of a G+12 reinforced concrete hospital building in Seismic Zone III (Zone Factor 0.16) using ETABS software. Three structural configurations are compared: the existing conventional structure, the structure retrofitted with steel bracing, and the structure retrofitted with RC jacketing. Parameters such as base shear, storey displacement, storey shear, storey stiffness, and natural frequency are analysed. Results show that RC jacketing yields the highest base shear (1051.98 kN), the lowest top-storey displacement (12.067 mm), and the greatest improvement in stiffness and natural frequencies, outperforming bracing in all aspects. Both retrofitting techniques significantly enhance lateral load resistance and seismic resilience compared to the existing condition. The study confirms that even in moderate seismic zones, retrofitting is essential for life safety and damage control. RC jacketing is recommended as a highly effective member-level retrofitting strategy for multi-storey RC frames.

References

Abbas S, Sharma J. A Review Paper on Design and Analysis of G+7 Building using ETABS. International Research Journal of Modernization in Engineering Technology and Science. 2022;4(1):783–786.

Agarwal, P., & Shrikhande, M. Earthquake Resistant Design of Structures. New Delhi: PHI Learning Private Limited; 2010.

Amritha Ranganadhan and Anju Paul, [Seismic Retrofitting of an Existing Structure], International Journal of Innovations in Engineering and Technology · April 2025, Volume: 04 Special Issue: 03, ISSN: 2321-7308.

Archana T. Kandy, Gul Jokhio and Abid Abu-Tair, [Seismic Retrofitting of Reinforced Concrete Structures under Different Retrofitting Schemes], International Journal of Structural and Civil Engineering Research Vol. 9, No. 1, February 2020 doi: 10.18178/ijscer.9.1.10-18.

Ayed Eid Alluqmani, [Effectiveness of Different Techniques on the Seismic Retrofitting of Existing RC Framed Buildings in Saudi Arabia], Saudi Journal of Civil Engineering, J Civ Eng, September, 2020; 4(7): 113-118.

Bidgar PA, Patel AV, Thakare NC. Analysis and Design of G+8 RCC Building using ETABS. International Journal of Scientific Research and Engineering Development. 2021;4(3):1683–1687.

Chandurkar PP, Pajgade PS. Seismic Analysis of RCC Building with and without Shear Wall. International Journal of Modern Engineering Research. 2013;3(3):1805–1810.

Chopra AK. Dynamics of Structures: Theory and Applications to Earthquake Engineering. 5th ed. New Delhi: Pearson Education; 2017.

Clough RW, Penzien J. Dynamics of Structures. 3rd ed. Berkeley: Computers and Structures Inc.; 2003.

CSI. ETABS Integrated Building Design Software User Guide. Berkeley, California: Computers and Structures Inc.; 2022.

Daljeet Pal Singh, [Seismic Analysis of G+12 Residential Building in Lucknow (Zone 3) Region and Study of RC Jacketing Technique for Retrofitting], International Research Journal of Engineering and Technology (IRJET), Volume: 06 Issue: 09 | Sep 2019, ISSN: 2395-0072.